Karfan þín er tóm
 

Tækniupplýsingar:

Staða á vöru:
  • Væntanlegt
    Ekki til á lager

Aðrar upplýsingar

Upplýsingar um vöru

Vörunúmer: 506500

Ljósdeyfir sem fellur í dós

Málafl: 200W

Málspenna: 230V

 

Features:

Function in the Gira One system
- Actuator for switching and dimming light bulbs, HV halogen lamps, dimmable HV LED lamps, dimmable compact fluorescent lamps, dimmable inductive electronic transformers with LV halogen lamps or LV LED lights, dimmable electronic transformers with LV halogen lamps or LV LED lights.
- 3 binary inputs for connection to conventional switches, buttons and motion detectors with zero-voltage contacts.
- The inputs are used to control Gira One actuators or to record status information.
- Automatic or manual selection of dimming principle according to load.
- Idle-state, short-circuit, and excess temperature-proof
- Power extension using power boosters.
- Connection to an external temperature sensor possible at input 3.
- Programming and commissioning using the Gira Project Assistant (GPA), from Version 5.0 (available from 03/2023).
- Encrypted data transfer between the Gira One devices.

Dimming outputs
- Minimum and maximum brightness can be set.
- Switch on to the last brightness value or permanently set switch-on brightness.
- Setting of a switch-on or switch-off delay.
- Staircase function; a pre-warning time and pre-warning brightness can also be set.

Binary inputs
- Single and double-surface operation can be configured for rocker buttons.
- Connection of rocker buttons parameterised with switching, dimming, shading and ventilation, scene call-up, staircase (motion detector), floor call, garage door and door opener functions.
- Connection of movement and presence detectors with zero-voltage relay outputs.
- Convenient group control of switching, dimming, shading and ventilation devices.
- Switching contact evaluation of wind, frost, brightness or rain sensors possible with zero-voltage relay contacts, in order to protect shading and ventilation devices from environmental influences.
- Window contact query and visualisation in the Smart Home App: An open window will result in the activation of the frost protection heating mode after a configured time has elapsed.
- Door contact query and visualisation in the Smart Home App: An open door results in the raising and locking of the blind or shutter.
- Query regarding a heating/cooling switchover on a heat pump, to allow the current operating mode (heating or cooling) to be forwarded to the heating controller.
- Switching contact display to show contact status in the Smart Home app.
- Configurable switching inputs that can be independently parameterised.
- Recording and comparison of temperature values via remote sensors (see accessories) at input 3.

Function in the Gira KNX system
- Switching and dimming of light bulbs, HV halogen lamps, dimmable HV-LED lamps, dimmable compact fluorescent lamps, dimmable inductive transformers with LV halogen or NV-LED lamps, dimmable electronic transformers with LV halogen or NV-LED lamps.
- Automatic or manual selection of dimming principle according to load.
- Idle-state, short-circuit, and excess temperature-proof
- Up to 8 independent logic functions for implementing simple or complex logical operations.
- Actively transmitting feedback or status messages can be delayed globally after a bus voltage recovery or ETS programming operation.

Dimming outputs
- The load type can be specified and the dimming principle defined: Universal (with automatic calibration procedure), electronic transformer (capacitive/trailing edge), conventional transformer (inductive/leading edge), LED (leading edge) or LED (trailing edge).
- Dimming characteristic configurable in time and value range for adaptation to the connected load.
- Dimmable range can be set (switch-on brightness; basic brightness; alternatively: lower dimming limit and upper dimming limit).
- Performance on receipt of an absolute brightness value can be set (dimming, brightening, fading).
- Performance during relative dimming up in switched-off state can be set ( switch channel on, no reaction).
- Central control function using up to 6 switching objects, 6 dimming objects and 6 value objects and collective feedback.
- Switching feedback: Active (transmitting to the bus cyclically or when there is a change) or passive (object can be read out) feedback function.
- Brightness value feedback: Active (transmitting to the bus cyclically or when there is a change) or passive (object can be read out) feedback function.
- For active feedback objects, the type of update can be set (when the input object is changed or when the feedback value is changed). This allows visualizations to be adapted individually.
- Feedback signals for short circuit, overload/mains power failure and load type (KNX-compliant and extended).
- Reaction in case of bus voltage failure/recovery can be set following an ETS programming process.
- Logical linking function for the output.
- Block function or alternative forced setting function can be parameterised.
- Time functions (switch-on delay, switch-off delay).
- Staircase light function with advance warning function via time-controlled reduction of lighting or activation of permanent lighting.
- Staircase function with time extension or variable staircase time allocation via communication object.
- Soft ON function and Soft OFF function can be set.
- Automatic switch-off can be set where brightness value < X % (with individual delay time).
- Can be integrated in the light scenes: Up to 64 internal scenes can be parametrised.
- Delay time for scene retrieval can be configured.
- Dimming performance can be set when a new scene is called up (brightening, dimming, fading).
- Visual feedback when saving a scene.
- Extended scene retrieval.
- Elapsed operating time meter can be activated.
- Elapsed operating time meter as forward meter (with optional threshold value) or backward meter (with optional starting value).


Technical data:
Rated voltage: DC 21 to 32 V SELV
Gira One Medium: Twisted pair (TP),
YCYM 2 x 2 x 0.8
Test voltage: 4 kV (KNX/EIB bus line)
Connections
- Gira One Bus: Connection terminals to control line
- Inputs: Connection terminals to control line
- Load: Screw terminals
Connections: Max. 4 mm²
Inputs
- Number: 3
Input type: Zero-voltage
Polling voltage
- Auxiliary inputs: Approx. 5 V
Total length
- Auxiliary input cable: Max. 10 m
Max. connected load
- Light bulbs: 20 to 230 W
- HV halogen lamps: 20 to 230 W
- Wound transformer: 20 to 210 VA
- Tronic transformer: 20 to 230 W
- Wound transformer with NV-LED: 20 to 100 VA
- electronic transformer with NV-LED: typically 20 to 200 W
- HV LED lamps: typically 1 to 200 W
Ambient temperature: -5 °C to +45 °C


Eiginleikar
Nafn eiginleika Gildi eiginleika
Tegund Ljósdeyfir
Kennilína Gira KNX
Málspenna 230 V
Málafl 200 W